DELL EMC D-PE-OE-23 Practice Exams
Last updated on Apr 02,2025- Exam Code: D-PE-OE-23
- Exam Name: Dell Technologies PowerEdge Operate 2023
- Certification Provider: DELL EMC
- Latest update: Apr 02,2025
A server needs to be configured with a six disk RAID 10 using 3 TB drives.
What should be the available array size in this configuration?
- A . 4TB
- B . 6TB
- C . 9TB
- D . 12TB
Which export type in iDRAC restores a Server Configuration Profile to a known baseline?
- A . Advanced
- B . Replacement
- C . Basic
- D . Clone
Which export type in iDRAC restores a Server Configuration Profile to a known baseline?
- A . Advanced
- B . Replacement
- C . Basic
- D . Clone
Which Dell PowerEdge 16G server has the highest GPU density to run workloads like HPC, AI, DB Analytics, and VDI?
- A . XR4520c
- B . XR7620
- C . XE8545
- D . XE8640
What happens when the Hardware Root of Trust fails to validate the BIOS?
- A . Boot Guard switches over to the backup BIOS and logs a warning in the system event log.
- B . Automated BIOS Recovery process recovers the BIOS from the DUP saved in the control panel.
- C . The server continues running and logs a critical error in the system event log.
- D . The server shuts down and logs a critical error in the system event log.
A technician is ready to deploy a server. If a critical part such as the system board fails, they must be able to replace the system board, reconfigure components, and update the firmware revisions in the fastest possible time.
How should the technician meet this requirement?
- A . Back up the profile using the System Profile Settings
- B . Use the iDRAC Rollback feature to restore the firmware revisions
- C . Use the iDRAC GUI to back up the Server Profile
- D . Back up component configurations using iSM
When does a customer require the Service Tag of the Dell EMC PowerEdge server?
- A . First time logging in to iDRAC
- B . First time accessing the BIOS
- C . Activating the OS
- D . Obtaining warranty information
A technician needs to perform a RAID controller firmware update from within the Operating System. The server runs Red Hat Enterprise Linux and is configured with an iDRAC basic license.
Which three steps should the technician take to complete this task? (Choose three.)
- A . R estart the server and press F10 t o start the firmware update process
- B . After firmware update, run fsck command on the virtual disks
- C . Obtain the latest firmware update for the RAID controller
- D . Run racadm fwupdate command from a management station
- E . Open a command shell and execute the firmware package
- F . After the firmware update, restart the server
Case Study 4
A company is experiencing a noticeable decrease in performance when accessing data on their Dell EMC Isilon cluster. The cluster hosts Microsoft Windows home directories and general purpose file shares. In addition, a file pool policy moves data that has not been modified in six months to an achieve tier.
The administrator wants your assistance in understanding the reason for the slow data access. The number of users accessing the cluster has not changed. The administrator has shared the following baseline metrics. The outputs were captured from a performance- acceptable time frame.
Trace route shows:
– 3 hops between clients and the cluster
– Average latency is 3 ms
Iperf shows:
– 940 Mb/s average bandwidth
– 005 ms average jitter
Netstat on the local network shows:
– 05% average re-transmission rate
Hostcache list:
– 20 ms average roundtrip time across all clients
The administrator shows you the following iperf output:
– 890 Mb/s average bandwidth
– 98.8 ms average jitter
Based on the output, what information should be provided to the administrator?
- A . Amount of jitter is in an acceptable range
- B . Numbers remain within the recommended range
- C . Lower than average bandwidth needs to be investigated
- D . Amount of jitter is an indication of network congestion
What type of fans are installed in servers with NVMe storage and GPU configurations?
- A . STD
- B . HPR
- C . LFM
- D . VHP