DELL EMC D-PSC-MN-01 Practice Exams
Last updated on Apr 14,2025- Exam Code: D-PSC-MN-01
- Exam Name: Dell PowerScale Maintenance
- Certification Provider: DELL EMC
- Latest update: Apr 14,2025
What status is an engineer trying to test if they run the isi_hwmon -s command?
- A . DIMM
- B . Sensor
- C . CPU
- D . Battery
- E . System
What is done with the components when a Gen6 single node is replaced?
- A . Transferred to the new node
- B . Returned to Dell
- C . Sent to WWFA
Refer to the exhibit.
A platform engineer has connected power cables to a Dell EMC PowerScale.
- A . Warning event
- B . On and healthy
- C . Cold and redundant
- D . Not functioning
Exhibit.
A platform engineer has connected power cables to a Dell PowerScale Gen6 node.
What does the status indicator indicate?
- A . Not functioning
- B . Cold and redundant
- C . Mismatch of voltage or component firmware
- D . On and healthy
Exhibit.
A platform engineer has connected power cables to a Dell PowerScale Gen6 node.
What does the status indicator indicate?
- A . Not functioning
- B . Cold and redundant
- C . Mismatch of voltage or component firmware
- D . On and healthy
What does a blue handle indicate on Dell EMC PowerScale Gen 6 hardware?
- A . Node should be shut down for maintenance procedures
- B . Hardware does not require ESD procedure
- C . Node can remain online during maintenance procedures
- D . Hardware does not require SolVe Desktop activity
A platform engineer is connecting a new Dell PowerScale F600 node to the frontend switch in an existing cluster with legacy nodes.
How should the network cables be connected?
- A . From the PCIe slot 1 to the frontend Ethernet switch
- B . From the PCIe slot 3 to the frontend Ethernet switch
- C . From the PCIe slot 1 to the frontend InfiniBand switch
- D . From the PCIe slot 3 to the frontend InfiniBand switch
Which document was replaced by the PEQ?
- A . Site Preparation and Planning Guide
- B . Web Administration Guide
- C . Supportability and Compatibility Guide
- D . Configuration Guide
A platform engineer has added an F200 node to a Dell EMC PowerScale cluster. The cluster now has five F200 nodes.
Before leaving the site, what action must the engineer perform?
- A . Verify the node LNN is set to 1
- B . SmartFail the node and rejoin the cluster
- C . Reboot the node and wait for a green status
- D . Ensure the install base record is updated
Which Dell EMC PowerScale Gen 6 components are considered CRUs?
- A . SSD, power supply, fan, and bezel
- B . Back-end switch, power supply, disk drive, and bezel
- C . SSD, power supply, disk drive, and bezel
- D . SSD, memory card, disk drive, and bezel