DELL EMC D-VXR-DY-01 Practice Exams
Last updated on Apr 05,2025 - Exam Code: D-VXR-DY-01
- Exam Name: Dell VxRail Deploy Exam
- Certification Provider: DELL EMC
- Latest update: Apr 05,2025
When validating the VxRail health just after the VxRail initial configuration, there is a red exclamation mark on the MARVIN-Virtual-SAN-Cluster and the reported health alarm is ‘Component metadata health’.
A "Retest" action in the health service panel is performed and all the nodes in the cluster show health status as failed with the invalid state. Investigation does not reveal any hardware issues with the disks in use by vSAN.
What action should be taken next?
- A . Wait 24 hours, then click the "Retest" button again
- B . Apply the vSphere ESXi600-201611001 patch, then click the "Retest" button again
- C . Evacuate and destroy the disk/disk group that contains the component(s) reporting errors and clear the alarm
- D . Reapply the MARVIN storage policy to the VxRail internal virtual machines
What is validated by running the Proactive VM Creation test in vCenter on a VxRail cluster?
- A . vSAN operates successfully
- B . Network firewalls are configured correctly
- C . vSAN has sufficient storage capacity
- D . Network performance is sufficient
In a VxRail deployment with an external vCenter Server, which VMware component(s) is automatically licensed?
- A . vCenter and vSphere only
- B . vSAN only
- C . vCenter, vSAN, and vSphere
- D . vCenter and vSAN only
A VxRail cluster has just been deployed. The administrator notices that Deduplication and Compression are not enabled.
What is the reason for this issue?
- A . The VSAN licensing is missing
- B . The service is disabled by default
- C . Nodes are configured with hybrid drives
- D . Nodes are configured with a single disk group
A VxRail cluster 4.7.xxx environment is managed by the internal vCenter Server. An implementation engineer plans to deploy a new VxRail cluster using the existing vCenter Server instance, then use the customer-supplied VDS to manage both VxRail clusters.
What must be done?
- A . Migrate the internal vCenter Server to an external vCenter Server, then merge the PSC
- B . Upgrade the VxRail version from 4.7.xxx to 7.0.000
- C . Migrate the internal vCenter Server to an external vCenter Server, then upgrade the VxRail 4.7.xxx to 7.0.100
- D . Upgrade the internal vCenter Server to version 7.0
How can an administrator manually verify DNS records for a VxRail implementation?
- A . ping
- B . ipconfig/all
- C . nslookup
- D . ping -a
What is the minimum configuration for a vSAN Stretched Cluster?
- A . 1+1 nodes and a witness
- B . 1+1 nodes and no witness
- C . 3+3 nodes and a witness
- D . 3+3 nodes and no witness
An implementation engineer is validating a VxRail deployment of six V570F nodes, each with four 10 Gb connections. The VxRail nodes have not been powered on.
Which command should they run to confirm that the Dell EMC ToR switch is configured correctly?
- A . show port-channel summary
- B . show interface status
- C . show lldp neighbors
- D . show running-config
The vCenter managing a VxRail cluster must be able to support both Enhanced Linked Mode and vSAN Encryption.
What is the correct configuration to satisfy this requirement?
- A . External vCenter External PSC
- B . Embedded vCenter Embedded PSC
- C . External vCenter Embedded PSC
- D . Embedded vCenter External PSC
What accurately describes VxRail G Series nodes?
- A . All nodes in a chassis must be identical.
- B . Different dot releases of the same major release are permitted if in different chassis.
- C . Each chassis must be fully populated.
- D . Hybrid and all-flash nodes are permitted if in different chassis.