Netapp NS0-014 Practice Exams
Last updated on Apr 06,2025- Exam Code: NS0-014
- Exam Name: NetApp Implementation Engineer MetroCluster Specialist (NCIE-MetroCluster)
- Certification Provider: Netapp
- Latest update: Apr 06,2025
What are two methods to verify that MetroCluster replication is functioning properly? (Choose two)
- A . Use the metrocluster check command
- B . Perform a data validation using Config Advisor
- C . Verify data consistency using SnapMirror
- D . Check IP route tables between sites
Which of the following is a major advantage of using IP MetroCluster over FC MetroCluster?
- A . Increased data redundancy
- B . Easier to deploy over long distances
- C . Reduced need for FC switches
- D . Lower bandwidth requirements
In a MetroCluster environment, which tool is used to validate the configuration before go-live?
- A . Config Advisor
- B . SnapMirror
- C . System Manager
- D . System Manager
Which component does the MetroCluster Tiebreaker software primarily interact with to monitor cluster health?
- A . SyncMirror
- B . FC switches
- C . Data ONTAP Mediator
- D . IP switches
Which two tasks should be completed after expanding a MetroCluster configuration? (Select two)
- A . Test inter-site connectivity and latency
- B . Reinstall the Mediator software
- C . Validate SyncMirror functionality
- D . Disconnect secondary sites temporarily
Which MetroCluster components require configuration for both FC and IP configurations? (Select two)
- A . Tiebreaker software
- B . ATTO bridges
- C . IP switches
- D . WAN connections
What are the major requirements for planning an IP-based MetroCluster deployment? (Select two)
- A . ATTO bridges
- B . High-capacity Ethernet links
- C . Fibre Channel connectivity
- D . Support for IP routing
When upgrading MetroCluster hardware, which two actions should be taken to minimize downtime? (Select two)
- A . Schedule the upgrade during peak usage hours
- B . Use Non-Disruptive Upgrade (NDU) for ONTAP upgrades
- C . Validate all hardware components with the Interoperability Matrix Tool (IMT)
- D . Avoid testing the configuration post-upgrade
What are two methods used to test failover in a MetroCluster configuration? (Choose two)
- A . Powering off a storage node
- B . Running the metrocluster switchover command
- C . Shutting down an FC switch
- D . Disconnecting the Mediator
What should you check in the IMT before performing a hardware expansion in a MetroCluster environment?
- A . Disk usage
- B . Compatibility of switches, controllers, and software
- C . Availability of spare parts
- D . Number of licensed users