NFPA CFPS Practice Exams
Last updated on Apr 09,2025- Exam Code: CFPS
- Exam Name: Certified Fire Protection Specialist (CFPS)
- Certification Provider: NFPA
- Latest update: Apr 09,2025
in assessing building life safely what are the four occupant response characteristics?
- A . Awareness reactivity location frailness
- B . Sensibility reactivity, mobility. susceptibility
- C . Cognition response physicality, familiarity
- D . Alertness remoteness, mobility, survivability
Fire alarm systems utilize what three (3) basic types of circuits?
- A . IDC, SLC, and NAC
- B . Class A,
- C . and C
- D . LEL, HEL, and MEL
- E . IDP, SIP, and NAP
Clean agents were developed and commercialized in direct response to the phase out of which halon pertaining to the Montreal Protocol?
- A . 1101
- B . 1201
- C . 1101
- D . 1401
What is the maximum allowable travel distance from any part of a smoke compartment to the door in a smoke barrier in a new health care facility?
- A . 50 ft. (15 m).
- B . 100 ft. (30 m).
- C . 150 ft. (46 m).
- D . 200 ft. (60 m).
After an emergency incident has occurred, a post-incident critique of the emergency preparedness procedure should be conducted covering the detection of the incident, implementation of incident command, and
- A . cause of the incident.
- B . notification, alerting and warning procedures.
- C . total time of the incident.
- D . where the incident occurred.
Hazardous materials (dangerous goods) are divided into now many numbered classes divided by Hazard and characteristics of material?
- A . 5
- B . 7
- C . 9
- D . 11
Panic hardware devices are designed to facilitate the release of the latching device on a door with a pressure note xceeding
- A . 5 pounds (2.3 kg.) is applied in the direction of exit travel.
- B . 10 pounds (4.5 kg.) is applied in the direction of exit travel.
- C . 15 pounds (6.8 kg.) is applied in the direction of exit travel.
- D . 20 pounds (9.1 kg.) is applied in the direction of exit travel.
Environmental Protection Agency standards require solid waste be treated as hazardous if it is a listed waste and/or meets the characteristics prescribed by the standard for toxicity, reactivity, corrosivity, and
- A . solubility.
- B . compactability.
- C . ignitability.
- D . treatability.
Probabilistic fire models are categorized into all of the following EXCEPT
- A . network.
- B . statistical.
- C . simulation.
- D . behavioral.
For standpipe systems containing 11/2 – 21/2 in. (40 – 65 mm) hose connection outlets without preconnected hose, a pressure regulating device is required when pressure exceeds
- A . 100 psi (689 kPa).
- B . 125 psi (862 kPa).
- C . 150 psi (1034 kPa).
- D . 175 psi (1207 kPa).